Scope
To supply an electric drive Pour Point Depressant injection package. Injection Rate: 0-1800 litres per hour Duty Process Pressure: 13.8 barg Fluid Viscosity: Up to 600 cP Ambient Temperature: -15 to +30 °C Skid ATEX Classification: Zone 2 IIA T3 Power Requirement: 440V 3ph 50hz Chemical reservoir: Tanker (by others)
Required Injection Rate: 0-1800 litres per hour
Duty Process Pressure: 13.8 barg
Fluid Viscosity: Up to 600 cP
Ambient Temperature: -15°C to 30°C
Skid ATEX Classification: Zone 2 IIA T3
Power Requirement: 440V 3ph 50hz
Chemical reservoir: Tanker (by others)
Solution
- ICR proposed SPX Flow Internal Gear Pumps in a duty/standby arrangement c/w variable speed electric motors
- Motor speed was locally controlled by a skid-mounted Ex d control panel
- Coriolis Flowmeter power supplied via the control panel
- On-skid equipment earthing provided along with On-skid cable support system
- Package was installed on a painted carbon-steel base frame c/w integral sloping drop tray with drain valve, certified lifting points, sling set and spreader lift beam
- Tubing, fittings, valves and components supplied in 316 stainless steel
- Discharge manifold fitted with dissimilar check valves for increased reliability
Results & Benefits
- Pumps capable of pumping viscous fluids at the required flowrate
- Bespoke control system configured to accept incoming power from client distribution board Overpressure safety built into design with discharge pressure relief valves
- Stable discharge flow and pressure through use of pulsation dampeners
- Real time flow rates and cumulative flow displayed locally on Coriolis flowmeter